2CPSA2A1B -
Safety Switch, Cable Pull, 2NC/2NO, Direct Opening, 120 Vac Multi-Cluster LED
- 制造商產(chǎn)品編號:
- 2CPSA2A1B
- 倉庫庫存編號:
- 70118520
由于產(chǎn)品數(shù)據(jù)庫龐大,部分產(chǎn)品信息可能未能及時更新,下單前請與銷售人員確認(rèn)好實時在庫數(shù)量,謝謝合作!
2CPSA2A1B產(chǎn)品概述
MICRO SWITCH 2CPS Series Cable Pull Safety Switch, Cable, Maintained Both Sides, 2NC/2NO Direct Opening (Switch 2, Left: 1NC/1NO; Switch 2, Right: 1NC/1NO), 1/2 NPT, Gold-plated Contacts, 120 Vac Multi-cluster LED. The 2CPS Cable Pull Safety Switch provides readily accessible emergency stop over a long, linear distance. It is a cost-effective means of providing this emergency stop signal compared to multiple emergency stop push buttons. (Cable Pull Safety Switches are not, however, to be used as a means of personnel safeguarding. They may be used to prevent further injury or damage to equipment when used for emergency stop signaling.)
The 2CPS Series Cable Pull Safety Switch is designed to provide emergency stop protection for exposed conveyor lines. The internal mechanism latches on both slackened cable (push) and pulled cable. This capability enhances productivity by eliminating nuisance stops due to variations in temperature, stretch of cable over time, and other application variables.
A line in the midpoint of the cable tension window indicates proper cable tension, providing easy and intuitive set-up. The direct acting switch contacts are held closed when the actuating cable is under proper tension and the reset knob is set to RUN. When the actuating cable is pulled, slackened or broken, a cam positively opens the NC (Normally Closed) switch contacts. The snap action, trip operation causes the switch contacts to change state and mechanically latch almost simultaneously when the cable is pulled, slackened or broken. The NC switch contacts remain open until the 2CPS is reset by properly tensioning the cable and manually rotating the reset knob.
When the direct acting switch contacts open, the auxiliary contacts also actuate (open contacts close and closed contacts open). The auxiliary contacts are electrically isolated from the direct acting switch contacts. These NO (Normally Open) contacts may be used for monitoring or signaling.
The 2CPS complies with: Low Voltage Directive 73/23/EEC, as amended by directive 93/68/EEC; Machinery Directive 98/37/EEC only as the directives relate to the components being used in a safety function; IEC/EN60947-1; IEC/EN60947-5-1; IEC/EN60947-5-5; UL, CE, CSA, SIL 3 capable.
Features:
Positive opening operation of normally closed contacts
Choice of 2NC/2NO or 3NC/1NO contact configurations
Maximum cable length in a single direction is 76 m (250 ft) for a combined length of 152 m (500 ft) in dual directions
Choice of three actuator configurations
Removable contact block version available
Large wiring cavity with straight-through wiring
24 Vdc or 120 Vac bright, multi-cluster LED status indicator light available
Gold-plated contacts are standard
Die-cast zinc housing
Optional hardware packs available
UL, CE, CSA, SIL 3 capable
Applications
Long conveyor systems found in warehouses and distribution centers
Conveyor systems having a high amount of vibration
Conveyor systems that experience wide temperature swings
Long conveyor systems where easy through wiring, or highly visible trip status is required
Perimeter guarding where hosedown conditions are present